ABSTRACT
Objective To explore the relationship between polymorphism of miR-499A > G with inci-dence and prognosis of colorectal cancer in Han Chinese. Method 1:1 matched case control study was used to collect samples,and the patients were followed up. The genotypes distribution miR-499A > G were detected by TaqMan probe,and logistic regression model and Cox proportional hazard regression model were used to analysis the relationship between miR-499A>G and incidence and prognosis of colorectal cancer. Results 394 cases and 394 controls were recruited,while miR-499A>G did not increase the risk of colorectal cancer(OR=1.22,95%CI:0.95-1.57)under additive model analyzed by multi-logistic regression model. The means of survival time of AA,AG,GG carriers were 54.19 ± 2.02,44.16 ± 2.59,32.76 ± 5.36 months and there were significant differentia-tion between them in log Rank test(F=11.24,P=0.004). Cox proportional hazard regression model showed that miR-499A > G was significant associated with adverse prognosis of colorectal cancer(HR=1.26,95%CI:1.02-1.57). Conclusion miR-499 A > G has no association with the incidence of colorectal cancer ,but it affects the prognosis of colorectal cancer in Han population.
ABSTRACT
Objective·To investigate the potential value of serum miRNAs for early diagnosis of acute coronary syndrome (ACS). Methods·Blood samples were collected from 28 emergency patients with suspected ACS in 3 h after enrollment. Eighteen patients were finally diagnosed as ACS and ten as non-ACS according to the ACS guideline. The expression levels of cardiac miR-499 and myocardial injury related miR-652 were measured with qRT-PCR. At the same time levels of troponin I (cTnI) were monitored. Then the correlations between miRNAs and cTnI were analyzed. In addition, 95% reference range was established. Results·The expression levels of serum miRNAs increased in ACS patients within 3 h and serum miR-499 in the ACS patients was 9.2 times the amount in the non-ACS patients (P=0.009). Serum miR-499 (r=0.595, P=0.001) and miR-652 (r=0.579, P=0.001) levels both had positive correlations with cTnI. The area under the ROC curve (AUC) of serum miR-499 and miR-652 was 0.786 and 0.583, respectively. The sensitivity and specificity of miR-499 were 72.22% and 80.00%, respectively, while 72.22% and 60.00% for miR-652. The reference ranges of serum miR-499 and miR-652 were 0.001-2.723 and 0.122-9.660, respectively. Conclusion·Cardiac miR-499 in serum has potential to be a biomarker for early diagnosis of ACS.
ABSTRACT
Objective·To investigate the potential value of serum miRNAs for early diagnosis of acute coronary syndrome (ACS). Methods·Blood samples were collected from 28 emergency patients with suspected ACS in 3 h after enrollment. Eighteen patients were finally diagnosed as ACS and ten as non-ACS according to the ACS guideline. The expression levels of cardiac miR-499 and myocardial injury related miR-652 were measured with qRT-PCR. At the same time levels of troponin I (cTnI) were monitored. Then the correlations between miRNAs and cTnI were analyzed. In addition, 95% reference range was established. Results·The expression levels of serum miRNAs increased in ACS patients within 3 h and serum miR-499 in the ACS patients was 9.2 times the amount in the non-ACS patients (P=0.009). Serum miR-499 (r=0.595, P=0.001) and miR-652 (r=0.579, P=0.001) levels both had positive correlations with cTnI. The area under the ROC curve (AUC) of serum miR-499 and miR-652 was 0.786 and 0.583, respectively. The sensitivity and specificity of miR-499 were 72.22% and 80.00%, respectively, while 72.22% and 60.00% for miR-652. The reference ranges of serum miR-499 and miR-652 were 0.001-2.723 and 0.122-9.660, respectively. Conclusion·Cardiac miR-499 in serum has potential to be a biomarker for early diagnosis of ACS.
ABSTRACT
Objective To evaluate the diagnostic value of microRNA-499 (miR-499)levels in acute myocardial infarction (AMI)diagnosis.Methods Retrieve Articles,Wanfang,China Knowledge Network,NCBI PubmMed,EMBSASE database 2010~2015 years met the inclusion criteria published abroad in relation to miR-499 diagnosis ten cases of human AMI litera-ture.The quality of the sudies was evaluated by QUADAS tools through a comprehensive analysis of the random effects model effect size,the use of meta-disc 1.4 software for statistical analysis software.Results Ten studies met the included criteria.The summary estimates for miR-499 diagnosis of MI sensitivity was 83% (95% CI,0.81 ~ 0.85),specificity of 81% (95% CI,0.78~0.83),positive predictive value of 4.53 (95% CI,3.12~ 6.58),negative predictive value was 0.22 (95% CI,0.14~0.33),diagnostic odds ratio 22.73 (95% CI,10.78~47.93).The area under the curve (AUC)for miR-499 was 0.90 with Q value of 0.84.Conclusion MiR-499 has high diagnostic value for acute myocardial infarction.